Q1 2026

Analyzing duplex formation with abdominal aortic aneurysm biomarker on palladium nanocube attached interdigitated electrodes

Guojian Li · Jiankun Chen · Xi Guo · Thangavel Lakshmipriya · Subash C.B. Gopinath · Yeng Chen · Lingjuan Du
10.25259/ajc_1097_2025 390 المشاهدات 0 الاقتباسات
0
الاقتباسات
390
المشاهدات
الملخص


Abdominal aortic aneurysm (AAA) is an inflated region in the lower part of body’s major artery (the aorta). Traditional screening methods of imaging are expensive, and researchers focus on alternative methods of biomarker screening with AAA detection. This research developed a method for duplex detection of two AAA biomarkers, namely, insulin like growth factor 1 (IGF1) and IGF binding proteins 1 (IGFBP1) for diagnosing AAA on palladium nanocube-modified interdigitated electrode (IDE) sensor. The probed surface with anti-IGFBP1 monoclonal antibody and anti-IGF1 aptamer was created on aminated palladium and performed the sensing with anti-IGF1 and anti-IGFBP1 antibodies. Palladium improved the probe attachment with aptamer-antibody on IDE surface and significantly enhanced the interactions of IGF1 and IGFBP1. The probe modified surface detects IGF1 and IGFBP1 as low as 10 fg/mL and 10 pg/mL with the R
2
values of 0.9183 [y = 0.1105x
2
– 0.2323x + 0.2181 R
2
= 0.9975], and 0.9032 [y = 0.1123x
2
– 0.2893x + 0.236 R
2
= 0.9953], respectively, on a linear regression. Further, control performances with closely related biomarkers namely C-reactive protein (CRP), N-terminal pro-B-type natriuretic peptide (NT-proBNP), and complementary aptamer sequence did not enhance the current and confirm specific detections IGF1 and IGFBP1. In addition, there is a current increment that was noted in IGF1 and IGFBP1 spiked serum samples without any interferences display the selective detection.

الاستشهاد بهذا المقال (APA)
Guojian, L., Jiankun, C., Xi, G., Thangavel, L., Subash, C. G., Yeng, C., Lingjuan, D. (2026). Analyzing duplex formation with abdominal aortic aneurysm biomarker on palladium nanocube attached interdigitated electrodes. Arabian Journal of Chemistry. https://doi.org/10.25259/ajc_1097_2025
أبحاث ذات صلة
67
استشهاد
816
54
استشهاد
1,354
42
استشهاد
964
38
استشهاد
1,078
29
استشهاد
2,106
الوصول
عرض النص الكامل عبر DOI
نُشر في
الرقم الدولي ISSN 1878-5352
الربعية Q1
درجة المؤشر القياس العربي 100
التخصص Natural Sciences
الناشر King Saud University / Elsevier
الدولة 🇸🇦 Saudi Arabia
عرض ملف المجلة →
المؤلفون
تفاصيل النشر
السنة 2026
اللغة English
أُضيف في 24 Jul 2026