Q3 2025

Estimation of the Optimum Etching Time and Etching Parameters for CR-39 Nuclear Tracks Detector by Applying Plasma and Chemical Etching Techniques

Abdulkader Makki Dahham · Jamoliddin Razzokov · Eldor Karimbaev · Raghad S. Mohammed
10.23851/mjs.v36i3.1699 391 المشاهدات 2 الاقتباسات
2
الاقتباسات
391
المشاهدات
الملخص

Background: CR-39 nuclear track detectors are widely used in various fields, including science, technology, astronomy, and environmental preservation, to detect and register heavy ions, neutrons, and alpha particles. Objective: This study aims to determine the optimal etching duration for CR-39 nuclear track detectors by comparing etching methods: The wet etching (using a water bath) and the dry etching technique (using dielectric barrier discharge (DBD) plasma). Methods: The traditional etching method involved immersing CR-39 detectors in a sodium hydroxide (NaOH) solution at 70 °C for varying durations. The dry etching method employed employs a non-thermal DBD plasma system to etch solid-state nuclear track detectors (SSNTDs) without the use of chemical solutions. Results: Photomicrographs revealed that tracks from chemical etching became clearly visible after 1 hour and developed at 5 hours. In contrast, the dry etching technique was significantly faster; tracks began to appear after just 1 minute of DBD plasma etching and were fully developed at 5 minutes. The optimum track density for DBD plasma was 20340±56 tracks/mm2 at 3 minutes, whereas the traditional water bath method achieved an optimum track density of 5238.0±5.7 tracks/mm2 at 2 hours. The shorter etching duration in the dry method likely facilitates the emergence of latent tracks without overlap. Conclusions: The bulk etch rate (VB) for CR-39 detectors using the dry DBD plasma etching technique was faster compared to the traditional chemical etching method. This demonstrates the efficacy of the dry etching process in significantly reducing etching time required for etching SSNDs.

الاستشهاد بهذا المقال (APA)
Abdulkader, M. D., Jamoliddin, R., Eldor, K., Raghad, S. M. (2025). Estimation of the Optimum Etching Time and Etching Parameters for CR-39 Nuclear Tracks Detector by Applying Plasma and Chemical Etching Techniques. Al-Mustansiriyah Journal of Science. https://doi.org/10.23851/mjs.v36i3.1699
أبحاث ذات صلة
Antimicrobial Efficacy of Quercetin against Biofilm Production by <i>Staphylococcus Aureus<…
Rayhana S. Najim; Mohsen Hashem Risan; Dhafar Najim Al-Ugaili · 2024
8
استشهاد
390
7
استشهاد
391
A Transfer Learning Approach for Arabic Image Captions
Haneen Siraj Ibrahim; Narjis Mezaal Shati; AbdulRahman A. Alsewari · 2024
7
استشهاد
389
الوصول
عرض النص الكامل عبر DOI
نُشر في
الرقم الدولي ISSN 1814-635X
الربعية Q3
درجة المؤشر القياس العربي 72
التخصص Natural Sciences
الناشر Al-Mustansiriyah University
الدولة 🇮🇶 Iraq
عرض ملف المجلة →
المؤلفون
تفاصيل النشر
السنة 2025
اللغة English
أُضيف في 23 Jul 2026