All systems operational
Q3 2026

RVAC as TAPSE/PASP and TAPSE*PVAT as a novel static parameter to assess fluid responsiveness in septic shock patients, a prospective cohort study

Soliman Belal Soliman · Mahmoud Mostafa Mahmoud · Mohamed Amin Fakher · Mahmoud Khaled Nour · Yasser Sadek Nassar
10.1007/s44349-025-00040-2 389 Views 0 Citations
0
Citations
389
Views
Abstract

Abstract

Introduction
A prospective cohort investigation was undertaken between November 2022 and April 2024, encompassing 50 patients with septic shock. The study evaluated fluid responsiveness through the assessment of right ventricular-arterial coupling (RVAC), quantified using the ratios TAPSE/PASP and TAPSE*PVAT, with left ventricular outflow tract velocity–time integral (LVOT-VTI) serving as the comparative parameter.


Aim of the study
Investigation of the association between non-invasive right ventricular-arterial coupling parameters and LVOT-VTI measurements post-fluid administration for predicting volume responsiveness in septic shock patients.


Methods
Each participant underwent fluid challenge protocols accompanied by standard echocardiographic evaluations. Right ventricular-arterial coupling parameters, including TAPSE/PASP and TAPSE*PVAT ratios, were documented to determine volume responsiveness. Patient stratification into responsive and non-responsive cohorts was established based on left ventricular outflow tract velocity–time integral (LVOT-VTI) alterations, with increases of ≥ 12% defining the responder category.


Results

The mean TAPSE/PASP was (0.63 ± 0.23 vs 0.42 ± 0.17,
P
 = 0.002, Cut-off: 0.47, AUC 0.764, 95% CI:]0.622–0.902[ specificity 78.1% and sensitivity 72.2%) in the responder vs the non-responder group respectively, The mean TAPSE*PVAT was (227.51 ± 45.67 vs 178.52 ± 52.37,
P
 = 0.003, Cut-off: 214.5, AUC 0.722, 95% CI:]0.618–0.896[specificity 71.3% and sensitivity 75%) in the responder vs the non-responder group respectively.



Conclusion
RVAC, expressed as TAPSE/PASP, demonstrated predictive value for fluid responsiveness in septic shock. TAPSE × PVAT may serve as an alternative non-invasive parameter.

Cite this Article (APA)
Soliman, B. S., Mahmoud, M. M., Mohamed, A. F., Mahmoud, K. N., Yasser, S. N. (2026). RVAC as TAPSE/PASP and TAPSE*PVAT as a novel static parameter to assess fluid responsiveness in septic shock patients, a prospective cohort study. The Egyptian Journal of Critical Care Medicine. https://doi.org/10.1007/s44349-025-00040-2
Related Papers
ECMO: The next ten years
Robert H. Bartlett · 2016
36
cites
391
35
cites
393
Impact of oral omega-3 fatty acids supplementation in early sepsis on clinical outcome and immunomod…
Mohamed Hosny; Rasha Nahas; Shereen Ali; Sanaa Abd Elshafei; Hassan Khaled · 2013
23
cites
398
The prognostic value of neuron specific enolase in head injury
Sameh El-Maraghi; Heba Yehia; Hazem Hossam; Ahmed Yehia; Hossam Mowafy · 2013
15
cites
392
Comparative study between elderly and younger patients with acute coronary syndrome
Mohammed Obaya; Moemen Yehia; Lamiaa Hamed; Alia Abdel Fattah · 2015
15
cites
391
Access
View Full Text via DOI
Published in
ISSN 2090-7303
Quartile Q3
AMS Score 57
Field Medicine & Health Sciences
Publisher Springer-Verlag
Country 🇪🇬 Egypt
View Journal Profile →
Authors
Publication Details
Year 2026
Language English
Added 14 Aug 2026