All systems operational
Q3 2026

Impact of pleural manometry in predicting non-expandable lung: a prospective study

Hany Hussein Moussa · Mohamed Mostafa Elsheikh · Noha Elsayed Mohamed · Walaa M. Eid
10.1186/s43168-026-00598-0 386 Views 0 Citations
0
Citations
386
Views
Abstract

Abstract

Background
Pleural manometry provides a real-time assessment of pleural pressure during thoracentesis and may aid in identifying non-expandable lung (NEL). Its diagnostic value relative to conventional pleural fluid biomarkers remains unclear.


Objective
To evaluate the diagnostic performance of pleural manometry in predicting non-expandable lung and to compare it with standard pleural fluid biochemical markers.


Methods
In this prospective observational study, 90 adults with pleural effusion undergoing therapeutic thoracentesis were enrolled. Pleural pressure was measured using a hemodynamic transducer during stepwise fluid removal. Pleural elastance (Pel) was calculated as the change in pleural pressure per unit volume removed. Lung expandability was determined based on post-procedure clinical and radiological assessment. Diagnostic performance was assessed using logistic regression and receiver operating characteristic (ROC) curve analysis.


Results

Non-expandable lung was identified in 35.6% of the studied patients. Pleural elastance showed excellent diagnostic accuracy (AUC = 0.970,
p
 < 0.001). A cutoff value of ≤ 14 cmH₂O/L predicted lung expandability with 98.3% sensitivity and 96.9% specificity. In contrast, pleural fluid biomarkers demonstrated moderate performance (AUC range: 0.759–0.848). Higher elastance values and more negative closing pressures were significantly associated with non-expandable lung and symptom development during thoracentesis.



Conclusion
Pleural elastance is a highly accurate and clinically useful predictor of lung expandability, outperforming conventional biochemical markers. Routine use of pleural manometry during thoracentesis may enhance procedural safety and support early identification of non-expandable lung.

Cite this Article (APA)
Hany, H. M., Mohamed, M. E., Noha, E. M., Walaa, M. E. (2026). Impact of pleural manometry in predicting non-expandable lung: a prospective study. Egyptian Journal of Bronchology. https://doi.org/10.1186/s43168-026-00598-0
Related Papers
Criteria and potential predictors of severity in patients with COVID-19
Niveen E. Zayed; Ahmad Abbas; Samah Mohamad Lutfy · 2022
24
cites
390
Serum interleukin-6 in chronic obstructive pulmonary disease patients and its relation to severity a…
Fatma G. M. Hussein; Randa S. Mohammed; Rasha A. Khattab; Laila A. Al-Sharawy · 2022
24
cites
390
Predictors of severity and mortality in COVID-19 patients
Hebatallah Hany Assal; Hoda M. Abdel-hamid; Sally Magdy; Maged Salah; Asmaa Ali; · 2022
19
cites
388
Protective mechanism of quercetin and its derivatives in viral-induced respiratory illnesses
Wahyu Choirur Rizky; Muhammad Candragupta Jihwaprani; Mazhar Mushtaq · 2022
10
cites
390
Access
View Full Text via DOI
Published in
ISSN 1687-8426
Quartile Q3
AMS Score 82
Field Medicine & Health Sciences
Publisher Springer (Biomed Central Ltd.)
Country 🇪🇬 Egypt
View Journal Profile →
Authors
Publication Details
Year 2026
Language English
Added 14 Aug 2026