Q3 2024

The quality of the electrodiagnostic referral system and the electrodiagnostic patterns in a sample of Egyptian patients

Mohamed Elsayed Nassif · Emmanuel Kamal Aziz Saba · Sarah Sayed El-Tawab · Wafaa Samir Elemary · Hoda Mohamed Abdelnaby · Naylan Fayez Wahba Khalil · Aya Hanafy Ibrahiem · Ahmed Mosaad Mohamed Arafa Elsakka · Nehad Mohamed Elshatby
10.1186/s43166-024-00282-5 386 المشاهدات 1 الاقتباسات
1
الاقتباسات
386
المشاهدات
الملخص

Abstract

Background
Electrodiagnosis is a localizing, diagnostic, and prognostic tool for individuals with suspected neuromuscular diseases. In addition to detailed history taking and thorough clinical examination, correct execution and interpretation of these tests can provide vital insights into the underlying neuromuscular disorders and frequently guide the need for proper management decision. The request for an electrodiagnosis examination should include brief clinical information and a provisional clinical diagnosis; this enhances the efficient easy performance of the test. The current study aims to detect the pattern of neuromuscular diseases in the Alexandria Main University Hospital, Egypt, and to evaluate the quality of the referral system to the electrodiagnosis unit.

Results
The study included 371 patients, out of which, 65% were referred from the Governmental Specialized Medical Councils and the Neurosurgery department. Although sensory complaints were the main reason for referral, yet 28.8% of patients did not show any electrodiagnosis abnormality. A compatible referral note led to shorter test times and fewer electromyography needle insertions.

Conclusion
Disorders of the peripheral nerves are the most frequent neuromuscular diseases referred to the electrodiagnosis unit with carpal tunnel syndrome being the most common disorder. A compatible referral letter is necessary when requesting an electrodiagnosis test, to save the physician time and focus on targeted procedures.

الاستشهاد بهذا المقال (APA)
Mohamed, E. N., Emmanuel, K. A. S., Sarah, S. E., Wafaa, S. E., Hoda, M. A., Naylan, F. W. K., Aya, H. I., Ahmed, M. M. A. E., Nehad, M. E. (2024). The quality of the electrodiagnostic referral system and the electrodiagnostic patterns in a sample of Egyptian patients. Egyptian Rheumatology and Rehabilitation. https://doi.org/10.1186/s43166-024-00282-5
أبحاث ذات صلة
Sleep quality, anxiety, depression, and quality of life in rheumatoid arthritis patients and impact …
Maha S. I. Abdelrahman; Ahmad M. Shaddad; Waleed Gamal Elddin Khaleel; Esraa A. · 2024
14
استشهاد
393
Serum malondialdehyde as a marker of oxidative stress in rheumatoid arthritis
Ghada A. Nabih; Nehal EEl Sheshtawy; Dalia M. E. El Mikkawy; Marwa A. Kamel · 2024
13
استشهاد
398
Vitamin D management update: evidence-based guidelines for vitamin D optimization by the Egyptian Ac…
Yasser El Miedany; Mathias Toth; Maha Mohamed El Gaafary; Safaa A. Mahran; Walee · 2025
10
استشهاد
395
TNF-α in the serum and synovial fluid of patients with rheumatoid arthritis: correlation with sonogr…
Aya El Hassany; Samar Tharwat; Mostafa Mansour; Asmaa Farouk Enein · 2024
8
استشهاد
392
Screening to prevent osteoporotic fractures in Egypt: a position statement of the Egyptian Academy o…
Yasser El Miedany; Maha El Gaafary; Naglaa Gadallah; Safaa Mahran; Mohamed Hassa · 2024
7
استشهاد
396
الوصول
عرض النص الكامل عبر DOI
نُشر في
الرقم الدولي ISSN 2090-3235
الربعية Q3
درجة المؤشر القياس العربي 76
التخصص Medicine & Health Sciences
الناشر Springer (Biomed Central Ltd.)
الدولة 🇪🇬 Egypt
عرض ملف المجلة →
المؤلفون
تفاصيل النشر
السنة 2024
اللغة English
أُضيف في 14 Aug 2026