Q4 2024

Investigation of the optimum neutron energy spectrum for brain tumor boron neutron capture therapy using Monte Carlo N-Particle Transport Code

Abdelfattah Soliman · Essam Banoqitah · Ned Xoubi · Fathi Djouider
10.4197/eng.34-1.5 389 المشاهدات 0 الاقتباسات
0
الاقتباسات
389
المشاهدات
الملخص

Boron neutron capture therapy, a targeted technique for cancer treatment, is based on fission reaction of implanted boron-10 in tumor cells by thermal neutrons to yield alpha particles and recoiling lithium‐7 nuclei. The short range of these ionizing fission products induces damages to the cancer cells while sparing surrounding healthy tissues. A methodology to determine the optimum neutron energy according to the depth of the tumor in the brain is developed in this work. This methodology mainly depends on separately considering the different reaction types at discrete neutron energies using Monte Carlo N-Particle (MCNP) Transport Code and investigating their relative contribution to the absorbed dose in both the tumor and surrounding healthy tissues. For a certain tumor depth, the neutron energy that maximizes the neutron dose to the tumor and minimizes it in the surrounding healthy tissues is selected. The metrics to evaluate improvement in the optimization process are developed based on the ratio of the tumor dose rate density (Gy/cm3‧s) to that of the surrounding healthy tissues. The results showed a significant improvement when compared with those of the International Atomic Energy Agency (IAEA) recommended neutron energy ranges. For deep-seated tumors, the dose ratio was improved from 0.89 to 1.77 for tissues preceding the tumor and from 2.40 to 12.0 for tissues after the tumor. For the shallow-seated tumors, the dose ratio was improved from 2.48 to 2.64 for tissues preceding the tumor and from 8.63 to 18.8 for tissues after the tumor.

الاستشهاد بهذا المقال (APA)
Abdelfattah, S., Essam, B., Ned, X., Fathi, D. (2024). Investigation of the optimum neutron energy spectrum for brain tumor boron neutron capture therapy using Monte Carlo N-Particle Transport Code. Journal of King Abdulaziz University: Engineering Sciences. https://doi.org/10.4197/eng.34-1.5
أبحاث ذات صلة
31
استشهاد
393
28
استشهاد
391
Domestic Water Quality in Jeddah, Saudi Arabia
Maged H. Hussein Maged H. Hussein · 2012
11
استشهاد
393
10
استشهاد
391
Suggestion Systems: A Usability-Based Evaluation Methodology
Mohammed Arif; Hani Aburas; Abdullah Al-Kuwaiti; Dennis Kulonda · 2010
9
استشهاد
390
الوصول
عرض النص الكامل عبر DOI
نُشر في
الرقم الدولي ISSN 1319-1047
الربعية Q4
درجة المؤشر القياس العربي 60
التخصص Engineering & Technology
الناشر King Abdulaziz University
الدولة 🇸🇦 Saudi Arabia
عرض ملف المجلة →
المؤلفون
تفاصيل النشر
السنة 2024
اللغة English
أُضيف في 28 Jul 2026