The use of cardiac magnetic resonance imaging for the evaluation of pulmonary hypertension

Shaima saeed Mohamed · Mona Mansour Ahmed · Tamer Mohamed Ali · Reem Ibrahim Elkorashy · Ahmed Mohamed Osman · Maryam Aly Abd Elkader · Sameh Nabil Kamel
10.4103/ecdt.ecdt_134_22 389 المشاهدات 0 الاقتباسات
0
الاقتباسات
389
المشاهدات
الملخص


Purpose
Evaluate the utility of cardiac magnetic resonance imaging to estimate the principle hemodynamic parameters that are measured by right heart catheterization in a noninvasive manner i.e. mean pulmonary artery pressure, pulmonary vascular resistance and pulmonary artery wedge pressure through cardiac magnetic resonance based numerical models.


Materials and methods
29 pulmonary hypertension patients, fitting the inclusion criteria were randomly selected and included in the study. CMR Imaging and right side heart catheter (RHC) were performed within one month. 3 Cardiac MRI based models in literature that showed high accuracy were tested. Two equations for mPAP calculation; mPAP=-231.423 + 53.8(loge inter-ventricular septal angle)+log10(right ventricular mass divided by left ventricular mass) i.e ventricular mass index X 8.708+area of pulmonary artery in diastole X 0.009 and mPAP = –4.6+(0.32*septal angle)+(ventricular mass index × 16.3). One equation for PAWP; PAWP = left atrial volume index +6.43 × 0.22.


Results
The Altman and Bland correlation between mPAP invasively measured and CMR-estimated mPAP had good correlation with r= 0.594 and r=0.599 (P<0.001) for CMR based mPAP model 1 and 2, respectively. The calculated mean bias between the RHC-derived and CMR-estimated mPAP was 7.9 (agreement interval -24.8 to 40.6 mm Hg) and mean bias -3 (agreement interval -34.8 to 28.2 mm Hg) for CMR based mPAP model 1 and 2, respectively. There was no correlation between invasively measured and CMR-estimated PAWP with (P =0.092) for CMR based PAWP model. The mean bias between the RHC-derived and CMR-estimated PAWP was 2.4 (agreement interval –13.5 to 18.2 mm Hg). The correlation between invasively calculated and CMR-estimated PVR had good correlation with r=0.703 and r=0.704 (P<0.001) for CMR based PVR model 1 and 2, respectively. The mean bias between the RHC-measured and CMR-estimated mPAP was 0.6 (agreement interval -11.6 to 12.8 mm Hg) and mean bias -1.3 (agreement interval -12.1 to 9.5 mm Hg) for CMR based mPAP model 1 and 2, respectively.


Conclusion
Our results showed good correlations between CMR findings and RHC as regard mPAP and PVR. Thus, estimation of mPAP, PAWP and PVR non-invasively using CMR is feasible but needs further studies to improve accuracy.

الاستشهاد بهذا المقال (APA)
Shaima, S. M., Mona, M. A., Tamer, M. A., Reem, I. E., Ahmed, M. O., Maryam, A. A. E., Sameh, N. K. (2024). The use of cardiac magnetic resonance imaging for the evaluation of pulmonary hypertension. Egyptian Journal of Chest Diseases and Tuberculosis. https://doi.org/10.4103/ecdt.ecdt_134_22
أبحاث ذات صلة
8
استشهاد
390
High velocity nasal insufflation versus non-invasive ventilation in acute respiratory failure: a com…
Aml A Abd El Aziz; Gehan A Abdelaal; Heba R Gasad; Bishoy B Tawadros · 2024
7
استشهاد
391
Role of right heart catheterization in diagnosis of pulmonary arterial hypertension
Samar M A Elmonim; Dalia E Elsharawy; Raghda G Elsheikh; Mohamed G A Elkholy · 2023
7
استشهاد
390
Transthoracic ultrasound in the diagnosis and follow-up of ventilator-associated pneumonia
Olfat M El-shinnawy; Mohamed Metwally; Nermeen Abdelaleem; Dina R R Gharieb · 2023
4
استشهاد
390
4
استشهاد
388
الوصول
عرض النص الكامل عبر DOI
نُشر في
الرقم الدولي ISSN 0422-7638
الربعية Q3
درجة المؤشر القياس العربي 73
التخصص Medicine & Health Sciences
الناشر Elsevier / Egyptian Society of Ches
الدولة 🇪🇬 Egypt
عرض ملف المجلة →
المؤلفون
تفاصيل النشر
السنة 2024
اللغة English
أُضيف في 27 Jul 2026